12/20kv Power Cables 3 Cores Cables to IEC 60502

Model NO.: N2XSEY, N2XSERY, N2XSEBY, N2XSEFGBY
Wire Core Material: Cu or Al
Certification: CCC, CE
Model: N2xsey, N2xsery, N2xseby, N2xsefgby
Brand: Jl
Rated Voltage: 12/20kv
Number of Core: 3
Refer Standard: IEC 60502-2
Trademark: JL
Transport Package: Wooden Drum/Steel Drum
Specification: 1.5-500Mm2
Origin: Jiangsu, China
HS Code: 8544492100
Model NO.: N2XSEY, N2XSERY, N2XSEBY, N2XSEFGBY
Wire Core Material: Cu or Al
Certification: CCC, CE
Model: N2xsey, N2xsery, N2xseby, N2xsefgby
Brand: Jl
Rated Voltage: 12/20kv
Number of Core: 3
Refer Standard: IEC 60502-2
Trademark: JL
Transport Package: Wooden Drum/Steel Drum
Specification: 1.5-500Mm2
Origin: Jiangsu, China
HS Code: 8544492100
12/20kv Power Cables 3 Cores Cables to IEC 60502


12/20kv Power Cables Three Cores Cables to IEC 60502 Standards

IEC 60502 Part 2(3.6/6KV to 18/30KV)

12/20kv Power Cables Three Cores Cables to IEC 60502 Application
The single core cables are designed for distribution of electrical power with nominal voltage Uo/U ranging from 1.8/3KV to 26/35KV and frequency 50Hz. They are suitable for installation mostly in power supply stations, indoors and in cable ducts, outdoors, underground and in water as well as for installation on cable trays for industries, switchboards and power stations.

12/20kv Power Cables Three Cores Cables to IEC 60502 Construction

Conductor: Plain annealed copper or aluminium complying with IEC 60228 class 1 or 2. 
Conductor Screen: 
The conductor screen consists of an extruded layer of non metallic, semi-conducting compound applied on top of a semi-conducting tape.
Insulation: Insulation is of polyvinyl chloride (PVC) intended for 1.8/3.6KV and 3.6/6KV cables, cross-linked polyethylene compound (XLPE)

Nom. Cross Section Area Insulation Thickness at Nominal Voltage
1.8/3KV 3.6/6KV 6/10KV 8.7/15KV 12/20KV 18/30KV 21/35KV 26/35KV
(Um=3.6KV) (Um=7.2KV) (Um=12KV) (Um=17.5KV) (Um=24KV) (Um=36KV) (Um=42KV) (Um=42KV)
mm2 mm mm mm mm mm mm mm mm
  XLPE XLPE XLPE XLPE XLPE XLPE XLPE XLPE
10 2 2.5 - - - - - -
16 2 2.5 3.4 - - - - -
25 2 2.5 3.4 4.5 - - - -
35 2 2.5 3.4 4.5 5.5 - - -
50 - 185 2 2.5 3.4 4.5 5.5 8 9.3 10.5
240 2 2.6 3.4 4.5 5.5 8 9.3 10.5
300 2 2.8 3.4 4.5 5.5 8 9.3 10.5
400 2 3 3.4 4.5 5.5 8 9.3 10.5
500 - 1600  2.2-2.8  3.2 3.4 4.5 5.5 8 9.3 10.5
Insulaton Screen:  The insulation screen consists of an extruded layer of non metallic, semi-conducting compound extruded over the insulation of each core. The extruded semi- conducting layer shall consist of bonded or cold strippable semi-conducting compound capable of removal for jointing or terminating.
Inner Covering & Fillers: The inner covering and fillers are made of non hygroscopic material like polypropylene.
Separation Sheath (for armoured cable): Extruded PVC, PE or LSZH, applied under the armour .
Lapped Bedding : The lapped bedding consists of Polyester non woven fabrics .
Armour (for armoured cable):  It consists of either flat galvanized steel wire armour (strip), round galvanized steel wire armour, and double steel tape armour.
Outer Sheath: PVC Or PE
Installation and operation condition of cable
Operating Temperature: up to 70°C (PVC insulation); up to 90°C (XLPE or EPR insulation)
Short Circuit Temperature( 5 seconds maximum duration ): 140-160°C (PVC insulation);
250°C (XLPE)
Bending Radius: 12 x OD
Current Rating Conditions:
Ground Temperature:
20°C
Ambient Temperature (air): 30°C
Depth of Soil: 0.8m
Thermal Resistance of Soil: 1.5K•m/W
Rated Voltage Uo/U Operating Voltage (Um) Testing Voltage
 (rms)
12/20KV 24KV 42KV  
 
12/20KV (Um=24KV) Power Cables Three Cores Cables to IEC 60502 Dimensional Data:
Nom.
Cross-Section Area
Nom.
Insulation Thickness
Copper Tape Thickness Copper Wire Screen Area*  Unarmoured Cables Steel Wire Armoured Cables
Nom.
Sheath Thickness
Approx.
Overall Diameter
Approx.
Weight
Nom.
Bedding Thickness
Armour Wire Size Nom.
Sheath Thickness
Approx.
Overall Diameter
Approx.
Weight
CU AL CU AL
mm2 mm mm mm2 mm mm kg/km mm mm mm mm kg/km
35 5.5 0.1 16 2.7 51 2850 2180 1.5 2.5 2.9 60 5700 5010
50 5.5 0.1 16 2.8 54 3340 2450 1.6 2.5 3 62 6370 5480
70 5.5 0.1 16 2.9 58 4150 2850 1.6 2.5 3.1 66 7370 6070
95 5.5 0.1 16 3 62 5110 3310 1.7 3.15 3.3 72 9400 7600
120 5.5 0.1 16 3.1 65 5990 3730 1.8 3.15 3.4 75 10530 8270
150 5.5 0.1 25 3.2 68 6980 4180 1.8 3.15 3.5 80 11800 8940
185 5.5 0.1 25 3.3 72 8240 4740 1.9 3.15 3.7 83 13350 9850
240 5.5 0.1 25 3.6 79 10310 5700 2 3.5 3.8 90 16430 11820
300 5.5 0.1 25 3.7 84 12360 6570 2.1 3.5 4 95 18870 13080
400 5.5 0.1 35 3.9 91 15220 7830 2.2 4 4.3 103 23260 15930
500 5.5 0.1 35 4.1 97 19105 10325 2.3 4.2 4.5 110 27800 19170

Nominal screen area, as stated in the table, can be supplied as standard.
Nom.
Cross-Section
Area
Steel Flat Wire Armoured Cables Double Steel Tape Armoured Cables
Nom.
Bedding Thickness
Armour Wire Size Nom.
Sheath Thickness
Approx.
Overall Diameter
Approx.
Weight
Nom.
Bedding Thickness
No of Steel Tapes x Nom Tape Thickness  Nom.
Sheath Thickness
Approx.
Overall Diameter
Approx.
Weight
CU AL CU AL
mm2 mm mm mm mm kg/km mm mm mm mm kg/km
35 1.5 0.8 2.7 55.7 5150 4530 1.5 2x0.5 2.8 56.5 4975 4355
50 1.6 0.8 2.8 58.2 5675 4935 1.6 2x0.5 2.9 59 5495 4750
70 1.6 0.8 2.9 61.9 6685 5570 1.6 2x0.5 3 62.7 6490 5375
95 1.7 0.8 3 66.4 7945 6390 1.7 2x0.5 3.1 67.2 7735 6180
120 1.8 0.8 3.1 70 9110 7103 1.8 2x0.5 3.2 70.8 8890 6880
150 1.8 0.8 3.2 73.2 10240 7770 1.8 2x0.5 3.3 74 10010 7535
185 1.9 0.8 3.3 77.7 11840 8750 1.9 2x0.5 3.4 78.5 11600 8500
240 2 0.8 3.5 83.2 14270 10070 2 2x0.8 3.6 85.5 14870 10680
300 2.1 0.8 3.6 88.6 16730 11440 2.1 2x0.8 3.8 91.1 17400 12130
400 2.2 0.8 3.9 95.6 20130 13350 2.2 2x0.8 4 97.9 20820 14050
500 2.3 0.8 4.1 103.3 24310 15600 2.3 2x0.8 4.2 105.6 25050 16350

12/20KV (Um=24KV) Power Cables Three Cores Cables to IEC 60502 Electrical Data
Nom. Cross- Section Area D C Resistance
CU / AL
A C Resistance
 CU / AL
Short Circuit Rating of Conductor
CU / AL
(1 sec)
Capaci tance Charging Current Short Circuit Rating of Copper Wire Screen Per Core(1 sec) Short Circuit Rating of Copper Tape Screen Per Core(1 sec) Reactance Inductance
mm² μΩ/m μΩ/m kA pF/m mA/m kA kA μΩ/m μΩ/m
35 524/868 668/1113 5.0/3.2 168 0.67 2.6 0.7 129 410
50 387/641 494/822 6.8/4.4 183 0.73 2.6 0.8 122 390
70 268/443 343/568 9.8/6.3 207 0.83 2.6 0.8 115 370
95 193/320 248/410 13.3/8.5 229 0.92 2.6 0.9 110 350
120 153/253 196/325 17.2/11.0 249 1 2.6 0.9 106 340
150 124/206 159/265 21.2/13.5 266 1.06 4.3 1 103 330
185 99.1/164 128/211 26.6/17.0 289 1.16 4.3 1 100 320
240 75.4/125 98/161 34.9/22.3 318 1.27 4.3 1.1 95 300
300 60.1/100 80/130 43.8/28.0 348 1.39 4.3 1.2 93 290
400 47.0/77.8 64/102 57.3/36.6 388 1.53 5.8 1.3 87 280
500 36.6/60.5 51/81 72.3/46.2 422 1.67 5.8 1.4 78 250


12/20kv Power Cables 3 Cores Cables to IEC 60502
12/20kv Power Cables 3 Cores Cables to IEC 60502
12/20kv Power Cables 3 Cores Cables to IEC 60502
12/20kv Power Cables 3 Cores Cables to IEC 60502
12/20kv Power Cables 3 Cores Cables to IEC 60502
  12/20kv Power Cables 3 Cores Cables to IEC 60502


12/20kv Power Cables Three Cores Cables to IEC 60502 Standards

IEC 60502 Part 2(3.6/6KV to 18/30KV)

12/20kv Power Cables Three Cores Cables to IEC 60502 Application
The single core cables are designed for distribution of electrical power with nominal voltage Uo/U ranging from 1.8/3KV to 26/35KV and frequency 50Hz. They are suitable for installation mostly in power supply stations, indoors and in cable ducts, outdoors, underground and in water as well as for installation on cable trays for industries, switchboards and power stations.

12/20kv Power Cables Three Cores Cables to IEC 60502 Construction

Conductor: Plain annealed copper or aluminium complying with IEC 60228 class 1 or 2. 
Conductor Screen: 
The conductor screen consists of an extruded layer of non metallic, semi-conducting compound applied on top of a semi-conducting tape.
Insulation: Insulation is of polyvinyl chloride (PVC) intended for 1.8/3.6KV and 3.6/6KV cables, cross-linked polyethylene compound (XLPE)

Nom. Cross Section Area Insulation Thickness at Nominal Voltage
1.8/3KV 3.6/6KV 6/10KV 8.7/15KV 12/20KV 18/30KV 21/35KV 26/35KV
(Um=3.6KV) (Um=7.2KV) (Um=12KV) (Um=17.5KV) (Um=24KV) (Um=36KV) (Um=42KV) (Um=42KV)
mm2 mm mm mm mm mm mm mm mm
  XLPE XLPE XLPE XLPE XLPE XLPE XLPE XLPE
10 2 2.5 - - - - - -
16 2 2.5 3.4 - - - - -
25 2 2.5 3.4 4.5 - - - -
35 2 2.5 3.4 4.5 5.5 - - -
50 - 185 2 2.5 3.4 4.5 5.5 8 9.3 10.5
240 2 2.6 3.4 4.5 5.5 8 9.3 10.5
300 2 2.8 3.4 4.5 5.5 8 9.3 10.5
400 2 3 3.4 4.5 5.5 8 9.3 10.5
500 - 1600  2.2-2.8  3.2 3.4 4.5 5.5 8 9.3 10.5
Insulaton Screen:  The insulation screen consists of an extruded layer of non metallic, semi-conducting compound extruded over the insulation of each core. The extruded semi- conducting layer shall consist of bonded or cold strippable semi-conducting compound capable of removal for jointing or terminating.
Inner Covering & Fillers: The inner covering and fillers are made of non hygroscopic material like polypropylene.
Separation Sheath (for armoured cable): Extruded PVC, PE or LSZH, applied under the armour .
Lapped Bedding : The lapped bedding consists of Polyester non woven fabrics .
Armour (for armoured cable):  It consists of either flat galvanized steel wire armour (strip), round galvanized steel wire armour, and double steel tape armour.
Outer Sheath: PVC Or PE
Installation and operation condition of cable
Operating Temperature: up to 70°C (PVC insulation); up to 90°C (XLPE or EPR insulation)
Short Circuit Temperature( 5 seconds maximum duration ): 140-160°C (PVC insulation);
250°C (XLPE)
Bending Radius: 12 x OD
Current Rating Conditions:
Ground Temperature:
20°C
Ambient Temperature (air): 30°C
Depth of Soil: 0.8m
Thermal Resistance of Soil: 1.5K•m/W
Rated Voltage Uo/U Operating Voltage (Um) Testing Voltage
 (rms)
12/20KV 24KV 42KV  
 
12/20KV (Um=24KV) Power Cables Three Cores Cables to IEC 60502 Dimensional Data:
Nom.
Cross-Section Area
Nom.
Insulation Thickness
Copper Tape Thickness Copper Wire Screen Area*  Unarmoured Cables Steel Wire Armoured Cables
Nom.
Sheath Thickness
Approx.
Overall Diameter
Approx.
Weight
Nom.
Bedding Thickness
Armour Wire Size Nom.
Sheath Thickness
Approx.
Overall Diameter
Approx.
Weight
CU AL CU AL
mm2 mm mm mm2 mm mm kg/km mm mm mm mm kg/km
35 5.5 0.1 16 2.7 51 2850 2180 1.5 2.5 2.9 60 5700 5010
50 5.5 0.1 16 2.8 54 3340 2450 1.6 2.5 3 62 6370 5480
70 5.5 0.1 16 2.9 58 4150 2850 1.6 2.5 3.1 66 7370 6070
95 5.5 0.1 16 3 62 5110 3310 1.7 3.15 3.3 72 9400 7600
120 5.5 0.1 16 3.1 65 5990 3730 1.8 3.15 3.4 75 10530 8270
150 5.5 0.1 25 3.2 68 6980 4180 1.8 3.15 3.5 80 11800 8940
185 5.5 0.1 25 3.3 72 8240 4740 1.9 3.15 3.7 83 13350 9850
240 5.5 0.1 25 3.6 79 10310 5700 2 3.5 3.8 90 16430 11820
300 5.5 0.1 25 3.7 84 12360 6570 2.1 3.5 4 95 18870 13080
400 5.5 0.1 35 3.9 91 15220 7830 2.2 4 4.3 103 23260 15930
500 5.5 0.1 35 4.1 97 19105 10325 2.3 4.2 4.5 110 27800 19170

Nominal screen area, as stated in the table, can be supplied as standard.
Nom.
Cross-Section
Area
Steel Flat Wire Armoured Cables Double Steel Tape Armoured Cables
Nom.
Bedding Thickness
Armour Wire Size Nom.
Sheath Thickness
Approx.
Overall Diameter
Approx.
Weight
Nom.
Bedding Thickness
No of Steel Tapes x Nom Tape Thickness  Nom.
Sheath Thickness
Approx.
Overall Diameter
Approx.
Weight
CU AL CU AL
mm2 mm mm mm mm kg/km mm mm mm mm kg/km
35 1.5 0.8 2.7 55.7 5150 4530 1.5 2x0.5 2.8 56.5 4975 4355
50 1.6 0.8 2.8 58.2 5675 4935 1.6 2x0.5 2.9 59 5495 4750
70 1.6 0.8 2.9 61.9 6685 5570 1.6 2x0.5 3 62.7 6490 5375
95 1.7 0.8 3 66.4 7945 6390 1.7 2x0.5 3.1 67.2 7735 6180
120 1.8 0.8 3.1 70 9110 7103 1.8 2x0.5 3.2 70.8 8890 6880
150 1.8 0.8 3.2 73.2 10240 7770 1.8 2x0.5 3.3 74 10010 7535
185 1.9 0.8 3.3 77.7 11840 8750 1.9 2x0.5 3.4 78.5 11600 8500
240 2 0.8 3.5 83.2 14270 10070 2 2x0.8 3.6 85.5 14870 10680
300 2.1 0.8 3.6 88.6 16730 11440 2.1 2x0.8 3.8 91.1 17400 12130
400 2.2 0.8 3.9 95.6 20130 13350 2.2 2x0.8 4 97.9 20820 14050
500 2.3 0.8 4.1 103.3 24310 15600 2.3 2x0.8 4.2 105.6 25050 16350

12/20KV (Um=24KV) Power Cables Three Cores Cables to IEC 60502 Electrical Data
Nom. Cross- Section Area D C Resistance
CU / AL
A C Resistance
 CU / AL
Short Circuit Rating of Conductor
CU / AL
(1 sec)
Capaci tance Charging Current Short Circuit Rating of Copper Wire Screen Per Core(1 sec) Short Circuit Rating of Copper Tape Screen Per Core(1 sec) Reactance Inductance
mm² μΩ/m μΩ/m kA pF/m mA/m kA kA μΩ/m μΩ/m
35 524/868 668/1113 5.0/3.2 168 0.67 2.6 0.7 129 410
50 387/641 494/822 6.8/4.4 183 0.73 2.6 0.8 122 390
70 268/443 343/568 9.8/6.3 207 0.83 2.6 0.8 115 370
95 193/320 248/410 13.3/8.5 229 0.92 2.6 0.9 110 350
120 153/253 196/325 17.2/11.0 249 1 2.6 0.9 106 340
150 124/206 159/265 21.2/13.5 266 1.06 4.3 1 103 330
185 99.1/164 128/211 26.6/17.0 289 1.16 4.3 1 100 320
240 75.4/125 98/161 34.9/22.3 318 1.27 4.3 1.1 95 300
300 60.1/100 80/130 43.8/28.0 348 1.39 4.3 1.2 93 290
400 47.0/77.8