Motor fault repair

Motor fault repair Failure phenomenon: Can not start after the motor is switched on

Cause and treatment:

1, the stator winding connection Error - Check wiring, correct errors 2, load, or the transmission is jammed - Check gear and the load 3, the power supply voltage is too low - Check the fault causes and negative <br> <br> Phenomenon: The motor housing is charged
Cause and treatment:

1, poor grounding or grounding resistance is too large - according to the provisions of good grounding, remove the bad grounding fault 2, the winding moisture - for drying treatment 3, insulation damage, lead touch shell - impregnated repair insulation, reconnect lead .

Symptom: The motor has a low speed with load

Cause and treatment:

1, the power supply voltage is too low - check the power supply voltage 2, the load is too large - check the load 3, broken rotor winding coil - replace the rotor

Yuhai company  offer custom  services including Piezo Ceramic Elements and piezo transducers, Yuhai people work closely with individual customers to provide solutions. We offer engineering support services including material selection, component design assistance, device and system modeling and failure analysis.